THE TRINITY CLOCK

 

 
 

Data

From to [ Shift -1 day | Shift +1 day ] Zoom menu

Plot and as with

Best fit to data (blue line). Reference gradient (red lines):-605ms/day/deg C.
this is for an uncompensated steel pendulum -605ms/day/C (we hope to acheive within 10ms/day/C with compensation)

Comments (see all | edit)

11 Nov 2010 [08:00]
TC works staff were checking out clearance in the pendulum case - they must have touched the pendulum
09 Nov 2010 [13:25]
ADJUST: -500 ms/day to 28700 Now that the pendulum is swinging nicely we can see that the temperature compensation is not ideal - sticking somewhere?
04 Nov 2010 [08:25]
ADJUST: +500 ms/day to 29200 maybe the new suspension is settling in. No matter how tight the screws are the spring will ratchet down against friction.

Download data

Interval between data points: seconds [either 3 seconds (weather data is duplicated) or multiples of 60 seconds (all data is averaged)].


Contact: clockkeeper@trin.cam.ac.uk, Trinity College, Cambridge